8502H

As our top one infant incubator is not a simple connection of incubator and phototherapy units. The sophisticated integration enable that newborn with hyperbilirubinemia could receive all around blue-ray phototherapy within an appropriate, sheltered and reliable environment. Every details including distance between phototherapy units and patient, illumination intensity and so on results from persistent and strict research and experience for your newborn patient while it is rigorously carrying out the duty of protecting infant with best possible care.
Enquiry 
  • Overview
  • Related Products

●Phototherapy light intensity is constantly adjustable 

●Time of bilirubin phototherapy can be paused, recorded and accumulated

●Phototherapy treatment duration can be pre-set and it automatically shuts off when a pre-set duration is reached

●Working life of LED phototherapy unit is lasting 20,000 hours

●Silicone mattress protect neonate from cauma while phototherapy treatment

●Microprocessor servo-controller ensures a precise and reliable temperature control

●Set temperature, monitored air temperature and baby skin temperature and heating power are distinguished in display

●Servo-controlled humidification system maintains the relative humidity at a constant level in the incubator

● Set and monitored humidity concentration are displayed separately

●Ultrasonic and low temperature nebulized humidification protects neonate from bacterias pollution

37 override temperature function

●Self-checking function for safety affirmative

●Audible and visible alarm indications for multiple failures with 3 priorities

●Chord alarm notes nurse farther than 8meters, but leaves asleep baby uninterrupted

●Aluminous framework for constant temperature keeping

●Continuous adjustment of mattress inclination up to 10º

●Drawer-type water reservoir is easily removable for cleaning and disinfection

●Nature air circulation system

●Cupboard cabinet

●RS-232 Connector

 Applications

The 8502H not only can keep a stable environment for neonate patient, but also can treat baby jaundice with intensive LED phototherapy simultaneously. With its compact design, ergonomics height adjustment and smooth trolley, the caregivers are easy to use it friendly in NICU. Widely applicable in all hospitals and clinics and optimize for preterm births or for some ill full-term babies or jaundiced baby.

 Optional Accessories

l  Side door, front-rear door

l  Double wall hood

l  Infant phototherapy unit (OSRAM tubes)