Classic-90

Our vital signs monitor can measure parameters of SpO2, NIBP, pulse, temperature, etc.It has a LCD screen for ECG and respiration waveforms.The vital signs monitor comes with a large LED color display which allows users to clearly see all values. Nellcor SpO2 technology is optional.
Enquiry 
  • Overview
  • Related Products
  1. Our vital signs monitor can measure parameters of SpO2, NIBP, pulse, temperature, etc. 
  2.  It has a LCD screen for ECG and respiration waveforms.
  3. The vital signs monitor comes with a large LED color display which allows users to clearly see all values.
  4.  Nellcor SpO2 technology is optional.
  5. The alarm limits are adjustable.
  6. The vital signs monitor offers Nurse Call function.
  7. It can store up to 12000 groups of NIBP data.
  8. Network capability with central monitoring system is available

Applications

 The vital signs monitor is an affordable patient monitor designed for simple and accurate vital signs assessment or continuous monitoring

Specifications 

Non-invasive Blood Pressure (NIBP)

Measurement Method

Oscillometric

 

Cuff Type

Standard

Adult

Optional

Pediatric or Neonatal

Inflation Time

≤ 10 sec (Typical Adult Cuff)

Defaulted Initial Cuff Inflation Pressure

Adult

180mmHg

Pediatric

120mmHg

Neonatal

90mmHg

Overpressure Protection Limit

Adult

300mmHg

Pediatric

240mmHg

Neonatal

145mmHg

Measurement Range

Systolic

Adult

40-275mmHg

Pediatric

40-200mmHg

Neonate

40-135mmHg

Diastolic

Adult

10-210mmHg

Pediatric

10-150mmHg

Neonate

10-95mmHg

MAP

Adult

20-230mmHg

Pediatric

20-165mmHg

Neonate

20-110mmHg

Measurement Accuracy

Mean Difference

≤ ±5mmHg

Standard Deviation

≤ 8mmHg

Measurement Mode

Manual, Auto & STAT

Cycle of Auto Mode

Setting Range

1-480minutes

Oxygen Saturation (SpO2)

Method

Dual-wavelength Optical

Measurement Range

1-100%

Measurement Accuracy

Arms≤ 3% at 70%-100%

(Arms is defined in ISO9919)

Pulse Rate

Pulse rate

30-250 bpm

(whichever is better)

±2bpm or ±2%

Others

Ambient Temperature

5-40

 

Relative Humidity

15%-90% (noncondensing)

Atmospheric Pressure

70-106kPa

Power Supply Voltage

100-240VAC

Power Supply Frequency

50/60Hz

Product Size and Weight

Dimensions

168mm(D)×172mm(W)×242mm(H)

Net Weight

2.4Kg

Gross Weight

4.7Kg

 

 