Classic-120Plus

Classic-120Plus multi-parameter monitor is designed and made on the basis of Classic-120 multi-parameter monitor. However, with a 12.1" color TFT display, it allows simultaneous display of up to 9 curves and can store up to 800 groups of NIBP data.
Enquiry 
  • Overview
  • Related Products

l  Classic-120Plus multi-parameter monitor offers visual and audible alarms with individual alarm setting.  

l  It has accessories for adult, neonatal and pediatric patients.

l  Maximum 480 hours trend graphs enable nearly all parameters and trends to be listed. 

l  Different mounting solutions are available, such as wall mounting and rolling stand mounting methods. 

l  The multi-parameter monitor can be networked with the central monitoring system.

 Applications

This multi-parameter monitor can be used for monitoring of parameters of ECG, RESP, NIBP, SpO2 and TEMP. Other optional monitoring applications are also available, such as mainstream, sidestream EtCO2 and 1 or 2-Channel IBP

Specifications

ECG

Heart rate display range

15bpm ~ 350bpm

Heart rate display accuracy

± 1% or ± 2bpm, whichever is greater

Sweeping speed

12.5mm /s, 25mm/s, 50mm/s

Sensitivity selection

×1/2, 5mm/mV ×1, 10mm/mV ×2, 20mm/mV

CMRR

≥ 89dB

RESP

Measuring range

0rpm~120rpm

Accuracy

±5% or ±2 rpm

Alarm limits setting range

0rpm~120rpm

TEMP

Measuring range

25.0 ~45.0

Measuring accuracy

±0.2

Responding time

≤150s

NIBP

Measuring method

Oscillometric Technique

Measuring range

0 mmHg~300mmHg

Accuracy

Maximal mean difference

±5 mmHg

Maximal standard deviation

8 mmHg

Measurement range

Adult

SYS 40 ~ 255 mmHg

MAP 20 ~ 215 mmHg

DIA 10 ~ 195 mmHg

Pediatric patient

SYS 40 ~ 200 mmHg

MAP 20 ~ 165 mmHg

DIA 10 ~ 150 mmHg

Neonate

SYS 40 ~ 135 mmHg

MAP 20 ~ 110 mmHg

DIA 10 ~ 95 mmHg

SpO2

Measuring range

35%~100%

Low perfusion capability

0.4%~5%

Accuracy

Not greater than 3% for SpOrange from 70% to 100%

PR

Measuring range

30bpm~240bpm

Measuring accuracy

±2bpm or ±2%, whichever is greater

 

 