l The UP-8000 multi-parameter monitor uses a 12.1" high resolution color LCD screen.
l It has a portable handset with wireless connection to main unit for data processing.
l The multi-parameter monitor offers optimized NIBP measurement modes for adult, neonatal and pediatric patients.
l It achieves automatic analysis of 20 arrhythmia waveforms.
l Both automatic and manual analysis is available for S-T segment.
l The patient monitor adopts digital SpO2 technology that helps ensure anti-motion and anti-low perfusion.
l It can store up to 400 groups of data as well as 24 hour ECG waveforms.
l The multi-parameter monitor offers protection against interference from defibrillator and electrosurgical generator.
l It has a built-in thermal printer.
Application
Our UP-8000 multi-parameter monitor is used for monitoring standard parameters of ECG, SpO2, RESP, NIBP, TEMP and PR. With a CSM module, it can also monitor parameters of CSI, EEG, EMG and BS% with alarms. The patient monitor is especially designed for anaesthesia use
Specifications
CSM |
EEG sensitivity |
±400μV |
|
Noise level |
<2μVp-p, <0.4μV RMS, 1~250Hz |
||
CMR |
>140dB |
||
Input impedance |
>50Mohm |
||
Sample rate |
2000 samples/sec. (14 bits equivalent) |
||
CSI and update |
0-100. Filter 6-42Hz, 1sec. update |
||
EMG |
0-100 logarithmic. Filter 75-85Hz, 1 sec. update |
||
BS% |
0-100%. Filter 2-42Hz, 1 sec. update |
||
Wireless range |
Up to 10 meters |
||
ECG |
Heart rate display range |
15bpm ~ 350bpm |
|
Heart rate display accuracy |
± 1% or ± 2bpm, whichever is greater |
||
Sweeping speed |
12.5mm/s, 25mm/s, 50mm/s |
||
Sensitivity selection |
×1/2, 5mm/mV ×1, 10mm/mV ×2, 20mm/mV |
||
CMRR |
≥ 89dB |
||
RESP |
Measuring range |
0rpm~120rpm |
|
Accuracy |
±5% or ±2 rpm |
||
Alarm limits setting range |
0rpm~120rpm |
||
TEMP |
Measuring range |
25.0 ℃ ~45.0℃ |
|
Measuring accuracy |
±0.2 ℃ |
||
Responding time |
≤150s |
||
NIBP |
Measuring method |
Oscillometric Technique |
|
Measuring range |
0mmHg~300mmHg |
||
Accuracy |
Maximal mean difference |
±5 mmHg |
|
Maximal standard deviation |
8 mmHg |
||
Measurement range |
Adult |
SYS 40 ~ 255 mmHg |
|
MAP 20 ~ 215 mmHg |
|||
DIA 10 ~ 195 mmHg |
|||
Pediatric patient |
SYS 40 ~ 200 mmHg |
||
MAP 20 ~ 165 mmHg |
|||
DIA 10 ~ 150 mmHg |
|||
Neonate |
SYS 40 ~ 135 mmHg |
||
MAP 20 ~ 110 mmHg |
|||
DIA 10 ~ 95 mmHg |
|||
SpO2 |
Measuring range |
35%~100% |
|
Low perfusion capability |
0.4%~5% |
||
Accuracy |
Not greater than 3% for SpO2 range from 70% to 100% |
||
PR |
Measuring range |
30bpm~240bpm |
|
Measuring accuracy |
±2bpm or ±2%, whichever is greater |
||
General |
Power supply |
100~240VAC, 50/60Hz |
|
Rechargeable Li-ion battery |
12V 2.3Ah |
||
Display mode |
12 inches TFT color LCD |
||
Alarming mode |
Audible and visible alarm |