classification

Newsletter

Contact our team

  • Heal Force Bio-meditech Holdings Limited
  • Add: 6788 Songze Avenue, Qingpu District, Shanghai 201706, China
  • Tel:+86-21-62728646
  • Fax:+86-21-62710529
  • E-mail:export@healforce.com
  • Contact person:Mr. Bill Shum
  • Website:www.healforce.com

Excelim-04

Excelim-04 is an innovative, computer-assisted surgical navigation system, which is widely used for surgical visualization, planning and navigation to help minimize iatrogenic trauma to the surrounding brain tissue and reduce risk for surgery complication in cranial procedures (like Neurology, cranial and ENT surgery).
Enquiry 
  • Overview
  • Related Products

 

l  Tomographic images in DICOM and captured with CT/C-arm/MRI/fMRI all are applicable in Excelim-04 surgical navigation system.

l  Advanced optical tracking system tracks real-time 3D position and orientation of active or passive markers attached to surgical tools, to deliver exceptional accuracy (spatial resolution 1.0mm) and reliability.

l  3D modeling and simulation method of anatomical structures in material (like skin, skull, brain tissue or target lesion) can be easily self-defined for surgical convenience.

l  With navigation probe and advanced optical measurement technology integrated, surgeon can easily quantify the size and position of lesions,  then design surgical approach the scientific way.

l  The system provides operators four navigation modes for all-round monitoring of navigation process.

l  The intelligent software will help calibrate and compensate for unexpected anatomical-structure change and brain shift induced by removal of intracranial lesion area.

l  Excelim-04 navigation system can be operated with surgeon mouse or touchmonitor mounted on the mobile cart or ceiling-suspension arm.

l  The system automatically save all patient image data and registration information, so as to let surgeon quickly load and continue surgical navigation against unexpected cut-off of electricity supply.

 

Application

Excelim-04 optical surgical navigation system can be used for all neurological and ENT surgeries, especially in deep-seated intracranial lesions, intracranial lesions of small volume, intracranial lesions of unclear invasive edge and minimally invasive surgeries. 

Copyright © 2022 Heal Force(力康生物医疗科技控股有限公司). All Rights Reserved.沪ICP备05005634号-5.logo沪公网安备31011802003750号
Home  |  Products  |  Solutions  |  Support & Download  |  News & Events  |  About Us  |  Contact Us